Wednesday, August 7, 2024

ARBURG CF DRIVE -  COMPACT FLASH DRIVE





Tuesday, January 3, 2023

Bosch PQ proportional valve.

 Used Bosch PQ proportional valve 0 811 402 105 with manifold for Arburg Allrounder Multronica and Centex Dialogica machines.





Monday, January 2, 2023

Bosch RKP 32: 7 Pistons-slipper pads with rotor

 




SPARE PART FROM USED BOSCH HYDAULIK PUMP RKP 32 : 0 514 500 343

 

7 Pistons- Slipper pads with rotor ( cylinder block) is available in good condition from the above mentioned pump.

This spare can be used  for Arburg Allrounder 221K, 305K ( Old toggle machines), Allrounder 220H, 270H,220D,270D.





Monday, March 11, 2013

Used Arburg injection molding machines available in March 2013

Used Arburg injection molding machines available in March 2013 :

Machine Model  YearClamping forceDistance bet. tiebarsShot wt.Screw dia.
KNmm x mmccmmm
270M  500-901991500270 x 270
20
270M 500-901991500270 x 270
25
320M 850-2101991850320 X 320
30
320-210-7501987750320 x 32035
220- 90-3501984350220 x 220
220D 350-901998350220 x 220





Note :Buyer and seller of Arburg machines can contact us with required details which can be displayed on this blog.

Sunday, February 24, 2013

Thermonic : Arburg temperature controller

Thermonic SN 46.531

Arburg injection moulding machine allrounder K, H and H-D have dedicated PID temperature controllers
for cylinder heating, nozzle heating  at the plasticizing unit.

These temperature controllers  i.e. Thermonics have a D-PID characteristics therefore, no temperature peak on start-up and no steady deviation. It has 3+1 configuration of Thermonics, i.e. 3 Thermonics for cylinder heating zones and one Thermonic for nozzle heating; ensures precise temperature profile on cylinder and nozzle.










Thermonic has an in- built under temperature protection circuit so that screw rotation is inhibited if
cylinder temperature is too low.

It consists of following main sections:
A. Input signal sampling and amplification.
B. PID regulation circuit.
C. Overload protection circuit &  SSR protection circuit.
D. Under temperature protection circuit.

There are many models of temperature controllers which were used on Arburg machines.

Thermonic SN 36.346, SN 31.980,SN 34.600, SN 39.507, SN 31.980 :  switching the supply to heater band via triac.

Thermonic  SN 40.787, SN 40.788, SN 46.530, SN 46.531, SN 52.022 :  switching the supply to heater band via SSR.

 Thermonic  SN 53.013, SN 71.356, SN 71.357  :  switching the supply to heater band via SSR.

Sanjadha Enterprises expertise in  repair and calibration of Thermonics of all models.
We have adequate stocks of spare parts and components required for repair of Thermonics.
We undertake complete overhaul, repair and reconditioning of Thermonics.


Thermonic SN 39.600













Thursday, February 14, 2013

Sanjadha Enterprises-our services for plastics industry

SANJADHA ENTERPRISES- SERVICES OFFERED TO PLASTIC INDUSTRY

1. Repair and calibration of Arburg PID temperature controller- Thermonic , all models on Arburg Allrounder K,H,H-D.
2.Repair of control unit- Polytronica-II ( black , white) for Arburg Allrounder K type (toggle) machines.
3.Repair of control unit- Hydronica ( thumbwheel type- Black and white) for Arburg Allrounder H type machines.
4.Repair of control unit- Hydronica H-D for ARBURG Allrounder D (Dialogica) models.
5.Repair of control unit- Multronica for Arburg Allrounder M.
6.Repair of control unit- Centex Dialogica (Allrounder C ) , Varima Dialogica (Allrounder V  ) and  CMD dialogica  ( Allrounder CMD).
7.Repair of control unit- Centex Selogica (Allrounder  CS) , Selecta-Selogica ( Allrounder S ).
8.Repair of power supply, amplifier PVS boards, Bosch regulation boards etc. on Arburg machines.
9.Temperature calibration of heating circuits on Arburg machines.
10.Retrofitting dummy drive for disketter drive system of H-D, M, CMD,V,C, CS and S models.
11.Pressure, flow calibration of Arburg machine for ARBURG K, H, D and M models.
12. Machine adjustment training on arburg machines.
13.Complete overhaul,reconditioning of Arburg machines : Seal change, toggle change,tie-bars change, alignment etc.
14.Power supply conditioning and upgradation for Arburg machines and other make of machines.
15.Repair of Techmation,Mirle,Focal,Porcheson PLCs.
16.Repair and calibration of Hot runner temperature controller e.g. Synventive, Mold Masters, Gammaflux etc.
17.Power supply conditioning and up gradation for hot runner temperature controllers.
18.Retrofitting of Arburg power supply kits, additional heating circuits, programmable input outputs, pressure reduction valve for screw safety etc.
19.Retofitting of PLC on Arburg injection moulding machines.
20.Retrofitting of  servo drive on Arburg injection moulding machines for power saving.
21.We also undertake repair of electronic boards such as amplifier boards,input-out board, interface board etc. for other brand of machines.