ARBURG CF DRIVE - COMPACT FLASH DRIVE
SANJADHA ENTERPRISES
Repair and calibration expert for Arburg Injection moulding machines,Arburg PID temperature controllers and Hot Runner Temperature controllers
Wednesday, August 7, 2024
Monday, January 1, 2024
Tuesday, January 3, 2023
Bosch PQ proportional valve.
Used Bosch PQ proportional valve 0 811 402 105 with manifold for Arburg Allrounder Multronica and Centex Dialogica machines.
Monday, January 2, 2023
Bosch RKP 32: 7 Pistons-slipper pads with rotor
SPARE PART
FROM USED BOSCH HYDAULIK PUMP RKP 32 : 0 514 500 343
7 Pistons- Slipper
pads with rotor ( cylinder block) is available in good condition from the above mentioned
pump.
This spare can be used for Arburg Allrounder 221K, 305K ( Old toggle machines), Allrounder 220H, 270H,220D,270D.
Monday, March 11, 2013
Used Arburg injection molding machines available in March 2013
Used Arburg injection molding machines available in March 2013 :
Note :Buyer and seller of Arburg machines can contact us with required details which can be displayed on this blog.
|
Note :Buyer and seller of Arburg machines can contact us with required details which can be displayed on this blog.
Sunday, February 24, 2013
Thermonic : Arburg temperature controller
Thermonic SN 46.531 |
Arburg injection moulding machine allrounder K, H and H-D have dedicated PID temperature controllers
for cylinder heating, nozzle heating at the plasticizing unit.
These temperature controllers i.e. Thermonics have a D-PID characteristics therefore, no temperature peak on start-up and no steady deviation. It has 3+1 configuration of Thermonics, i.e. 3 Thermonics for cylinder heating zones and one Thermonic for nozzle heating; ensures precise temperature profile on cylinder and nozzle.
Thermonic has an in- built under temperature protection circuit so that screw rotation is inhibited if
cylinder temperature is too low.
It consists of following main sections:
A. Input signal sampling and amplification.
B. PID regulation circuit.
C. Overload protection circuit & SSR protection circuit.
D. Under temperature protection circuit.
There are many models of temperature controllers which were used on Arburg machines.
Thermonic SN 36.346, SN 31.980,SN 34.600, SN 39.507, SN 31.980 : switching the supply to heater band via triac.
Thermonic SN 40.787, SN 40.788, SN 46.530, SN 46.531, SN 52.022 : switching the supply to heater band via SSR.
Thermonic SN 53.013, SN 71.356, SN 71.357 : switching the supply to heater band via SSR.
We have adequate stocks of spare parts and components required for repair of Thermonics.
We undertake complete overhaul, repair and reconditioning of Thermonics.
Thermonic SN 39.600 |
Thursday, February 14, 2013
Sanjadha Enterprises-our services for plastics industry
SANJADHA ENTERPRISES- SERVICES OFFERED TO PLASTIC INDUSTRY
1. Repair and calibration of Arburg PID temperature controller- Thermonic , all models on Arburg Allrounder K,H,H-D.
2.Repair of control unit- Polytronica-II ( black , white) for Arburg Allrounder K type (toggle) machines.
3.Repair of control unit- Hydronica ( thumbwheel type- Black and white) for Arburg Allrounder H type machines.
4.Repair of control unit- Hydronica H-D for ARBURG Allrounder D (Dialogica) models.
5.Repair of control unit- Multronica for Arburg Allrounder M.
6.Repair of control unit- Centex Dialogica (Allrounder C ) , Varima Dialogica (Allrounder V ) and CMD dialogica ( Allrounder CMD).
7.Repair of control unit- Centex Selogica (Allrounder CS) , Selecta-Selogica ( Allrounder S ).
8.Repair of power supply, amplifier PVS boards, Bosch regulation boards etc. on Arburg machines.
9.Temperature calibration of heating circuits on Arburg machines.
10.Retrofitting dummy drive for disketter drive system of H-D, M, CMD,V,C, CS and S models.
11.Pressure, flow calibration of Arburg machine for ARBURG K, H, D and M models.
12. Machine adjustment training on arburg machines.
13.Complete overhaul,reconditioning of Arburg machines : Seal change, toggle change,tie-bars change, alignment etc.
14.Power supply conditioning and upgradation for Arburg machines and other make of machines.
15.Repair of Techmation,Mirle,Focal,Porcheson PLCs.
16.Repair and calibration of Hot runner temperature controller e.g. Synventive, Mold Masters, Gammaflux etc.
17.Power supply conditioning and up gradation for hot runner temperature controllers.
18.Retrofitting of Arburg power supply kits, additional heating circuits, programmable input outputs, pressure reduction valve for screw safety etc.
19.Retofitting of PLC on Arburg injection moulding machines.
20.Retrofitting of servo drive on Arburg injection moulding machines for power saving.
21.We also undertake repair of electronic boards such as amplifier boards,input-out board, interface board etc. for other brand of machines.
1. Repair and calibration of Arburg PID temperature controller- Thermonic , all models on Arburg Allrounder K,H,H-D.
2.Repair of control unit- Polytronica-II ( black , white) for Arburg Allrounder K type (toggle) machines.
3.Repair of control unit- Hydronica ( thumbwheel type- Black and white) for Arburg Allrounder H type machines.
4.Repair of control unit- Hydronica H-D for ARBURG Allrounder D (Dialogica) models.
5.Repair of control unit- Multronica for Arburg Allrounder M.
6.Repair of control unit- Centex Dialogica (Allrounder C ) , Varima Dialogica (Allrounder V ) and CMD dialogica ( Allrounder CMD).
7.Repair of control unit- Centex Selogica (Allrounder CS) , Selecta-Selogica ( Allrounder S ).
8.Repair of power supply, amplifier PVS boards, Bosch regulation boards etc. on Arburg machines.
9.Temperature calibration of heating circuits on Arburg machines.
10.Retrofitting dummy drive for disketter drive system of H-D, M, CMD,V,C, CS and S models.
11.Pressure, flow calibration of Arburg machine for ARBURG K, H, D and M models.
12. Machine adjustment training on arburg machines.
13.Complete overhaul,reconditioning of Arburg machines : Seal change, toggle change,tie-bars change, alignment etc.
14.Power supply conditioning and upgradation for Arburg machines and other make of machines.
15.Repair of Techmation,Mirle,Focal,Porcheson PLCs.
16.Repair and calibration of Hot runner temperature controller e.g. Synventive, Mold Masters, Gammaflux etc.
17.Power supply conditioning and up gradation for hot runner temperature controllers.
18.Retrofitting of Arburg power supply kits, additional heating circuits, programmable input outputs, pressure reduction valve for screw safety etc.
19.Retofitting of PLC on Arburg injection moulding machines.
20.Retrofitting of servo drive on Arburg injection moulding machines for power saving.
21.We also undertake repair of electronic boards such as amplifier boards,input-out board, interface board etc. for other brand of machines.
Subscribe to: